Signal Path
- When the power switch is turned ON, power ON power supply is supplied to the VCM from the IPDM E/R.
- The VCM detects whether or not the normal or quick charge connector is connected based on the EVSE connection signal from the PDM (Power Delivery Module) or the quick charger connection signal. When the normal or quick charge connector is connected, the VCM transmits the remove charge connector warning signal to the combination meter.
- When the combination meter receives the remove charge connector warning signal, it displays the remove charge connector warning on the vehicle information display.