Signal Path
- When the charge connector is connected to the normal charge port, PDM (Power Delivery Module) transmits an EVSE connecting signal to VCM.
- When the charge connector is connected to the quick charge port, PDM (Power Delivery Module) transmits a quick charger connecting signal to VCM.
- When receiving an EVSE connecting signal or quick charger connecting signal, VCM supplies power to the plug in indicator lamp located in the combination meter and turns ON the plug in indicator lamp.NOTE: When EVSE or normal charging device is connected to the normal charge port, the indicator lamp turns OFF if no operation is performed for ten consecutive seconds or more.