Diagnosis Procedure
- PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Refer to Work Procedure .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace the malfunctioning parts.
- CHECK DOOR WINDOW SLIDING PART
- Foreign material contacts window glass or glass run rubber.
- Glass run rubber wear or deformation.
- Sash is tilted too much or not enough.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace the malfunctioning parts.
- CHECK ENCODER CIRCUIT
Check encoder circuit.
Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
Check intermittent incident. Refer to Inspection .
NO
Repair or replace the malfunctioning parts.