DTC Detection Logic
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1 signal is not inordinately high.
|
DTC No. |
CONSULT screen terms (Trouble diagnosis content) |
DTC detecting condition |
Possible cause |
|
P0132 |
A/F SENSOR1 (B1) (O2 sensor circuit high voltage bank 1 sensor 1) |
The A/F signal computed by ECM from the A/F sensor 1 signal is constantly approx. 5 V. |
|