Removal And Installation: Installation
Installation is in the reverse order of removal.
CAUTION:
Be sure to tighten "B" terminal nut carefully.
| "B" terminal nut | : 10.1 N•m (1.0 kg-m, 7 ft-lb) |
- Install generator and check tension of belt. Refer to CHECKING DRIVE BELT .
- For this model, the power generation voltage variable control system that controls the power generation voltage of the generator has been adopted. Therefore, the power generation voltage variable control system operation inspection should be performed after replacing the generator, and then make sure that the system operates normally. Refer to DIAGNOSIS PROCEDURE .
- Recharge A/C refrigerant. Refer to CHARGE REFRIGERANT
.CAUTION:
Apply A/C oil to the O-ring of the low-pressure flexible hose for installation.