Calibration Of DECEL G Sensor

CAUTION:

To calibrate the decel G sensor, make sure to use CONSULT.

(Calibration cannot be done without CONSULT).

  1. ALIGN THE VEHICLE STATUS

    Stop vehicle with front wheels in straight-ahead position.

    GO TO STEP 2 

  2. PERFORM CALIBRATION OF DECEL G SENSOR

    1. On the CONSULT screen, touch "Work support" and "DECEL G SEN CALIBRATION" in order.
    2. Touch "Start".
    3. After approximately 10 seconds, touch "End".
      NOTE:

      After approximately 60 seconds, it ends automatically.

    4. Turn ignition switch OFF, then turn it ON again.
      CAUTION:

      Be sure to perform above operation.

    GO TO STEP 3 

  3. CHECK DATA MONITOR

    1. Run vehicle with front wheels in straight-ahead position, then stop.
    2. Select "Data Monitor". Then make sure "DECEL G SEN" is within +- 0.08G.

    Is the inspection result normal?

    YES 

    GO TO STEP 4 

    NO 

    Perform calibration of decel G sensor again, GO TO STEP 1 

  4. ERASE THE SELF-DIAGNOSIS MEMORY

    Erase the self-diagnosis memory of the ABS actuator and electric unit (control unit) and ECM.

    Are the memories erased?

    YES 

    Inspection End

    NO 

    Check the items indicated by the self-diagnosis.