Physical Values
| Terminal No. (wire color) | Description | Condition | Voltage (V) | ||
|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||
| 1 (O) | Ground | Sliding door power window motor LH UP signal | Output | When sliding door LH switch in power window main switch is in UP operation. | 9 - 16 |
| 2 (W) | Ground | Encoder ground | - | - | 0 - 1 |
| 3 (BR) | Ground | Sliding door power window motor LH DOWN signal | Output | When sliding door LH switch in power window main switch is in DOWN operation. | 9 - 16 |
| 4 (P) | Ground | Door key cylinder switch LOCK signal | Input | Key position (Neutral → Locked) |
4 - 6 → 0 - 1.5 |
| 5 (SB) | Ground | Sliding door power window motor RH DOWN signal | Output | When sliding door RH switch in power window main switch is in DOWN operation. | 9 - 16 |
| 6 (GR) | Ground | Door key cylinder switch UNLOCK signal | Input | Key position (Neutral → Unlocked) |
4 - 6 → 0 - 1.5 |
| 7 (P) | Ground | Sliding door power window motor RH UP signal | Output | When sliding door RH switch in power window main switch is in UP operation. | 9 - 16 |
| 8 (L) | Ground | Front power window motor (driver side) UP signal | Output | When front LH switch in power window main switch is in UP operation. | 9 - 16 |
| 9 (SB) | Ground | Encoder pulse signal 2 | Input | When power window motor operates. | |
| 10 (V) | Ground | Retained power signal | Input | Ignition switch ON | 9 - 16 |
| Within 45 seconds after ignition switch is turned to OFF. | 9 - 16 | ||||
| When driver side or passenger side door is opened during retained power operation. | 0 - 1 | ||||
| 11 (LG) | Ground | Front power window motor (driver side) DOWN signal | Output | When front LH switch in power window main switch is in DOWN operation. | 9 - 16 |
| 13 (Y) | Ground | Encoder pulse signal 1 | Input | When power window motor operates. | |
| 14 (BR) | Ground | Power window serial link | Input/Output | Ignition switch ON or power window timer operating. | |
| 15 (R) | Ground | Encoder power supply | Output | When ignition switch ON or power window timer operates. | 9 - 16 |
| 17 (B) | Ground | Ground | - | - | 0 - 1 |
| 19 (LG) | Ground | Battery power supply | Input | - | 9 - 16 |