| 1 (O) |
Ground |
Sliding door power window motor LH UP signal |
Output |
When sliding door LH switch in power window main switch is in UP operation. |
9 - 16 |
| 2 (W) |
Ground |
Encoder ground |
- |
- |
0 - 1 |
| 3 (BR) |
Ground |
Sliding door power window motor LH DOWN signal |
Output |
When sliding door LH switch in power window main switch is in DOWN operation. |
9 - 16 |
| 5 (SB) |
Ground |
Sliding door power window motor RH DOWN signal |
Output |
When sliding door RH switch in power window main switch is in DOWN operation. |
9 - 16 |
| 7 (P) |
Ground |
Sliding door power window motor RH UP signal |
Output |
When sliding door RH switch in power window main switch is in UP operation. |
9 - 16 |
| 8 (BR) |
Ground |
Front power window motor (passenger side) UP signal |
Output |
When front RH switch in power window main switch is in UP operation. |
9 - 16 |
| 9 (SB) |
Ground |
Encoder pulse signal 2 |
Input |
When front power window motor (driver side) operates. |
|
| 10 (V) |
Ground |
Retained power signal |
Input |
Ignition switch ON |
9 - 16 |
| Within 45 seconds after ignition switch is turned to OFF. |
9 - 16 |
| When driver side or passenger side door is opened during retained power operation. |
0 - 1 |
| 11 (GR) |
Ground |
Front power window motor (passenger side) DOWN signal |
Output |
When front RH switch in power window main switch is in DOWN operation. |
9 - 16 |
| 12 (LG) |
Ground |
Front power window motor (driver side) DOWN signal |
Output |
When front LH switch in power window main switch is in DOWN operation. |
9 - 16 |
| 13 (Y) |
Ground |
Encoder pulse signal 1 |
Input |
When front power window motor (driver side) operates. |
|
| 15 (R) |
Ground |
Encoder power supply |
Output |
When ignition switch ON or power window timer operating. |
9 - 16 |
| 16 (L) |
Ground |
Front power window motor (driver side) UP signal |
Output |
When front LH switch in power window main switch is in UP operation. |
9 - 16 |
| 17 (B) |
Ground |
Ground |
- |
- |
0 - 1 |
| 19 (LG) |
Ground |
Battery power supply |
Input |
Ignition switch OFF |
9 - 16 |