Diagnosis Procedure
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect cooling fan control nodule harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control nodule harness connector and ground.
+ - Voltage Cooling fan control module Connector Terminal E203 3 Ground Battery voltage Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 2.
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect cooling fan relay harness connector.
- Check the continuity between cooling fan control nodule harness connector and cooling fan relay harness connector.
+ - Continuity Cooling fan control module Cooling fan relay Connector Terminal Connector Terminal E203 3 E204 3 Existed - Also check harness for short to ground.
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY POWER SUPPLY CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between cooling fan relay harness connector and IPDM E/R harness connector.
+ - Continuity Cooling fan relay IPDM E/R Connector Terminal Connector Terminal E204 1 E17 67 Existed - Also check harness for short to ground.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY
Check cooling fan relay. Refer to "COMPONENT INSPECTION (COOLING FAN RELAY) ".
Is the inspection result normal?
YES: Perform the trouble diagnosis for power supply circuit.
NO: Replace cooling fan relay. Refer to "STANDARDIZED RELAY ".
- CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan control nodule harness connector and ground.
+ - Continuity Cooling fan control module Connector Terminal E203 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between cooling fan control nodule harness connector and IPDM E/R harness connector.
+ - Continuity Cooling fan control module IPDM E/R Connector Terminal Connector Terminal E203 2 E17 72 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL CIRCUIT
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan control module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module terminals and ground.
+ - Voltage Cooling fan control module Connector Terminal E301 4 Ground Battery voltage E302 6 Is the inspection result normal?
YES: GO TO 8.
NO: Repair or replace error-detected parts.
- CHECK COOLING FAN MOTORS -1 AND -2
Check the cooling fan motor. Refer to "COMPONENT INSPECTION (COOLING FAN MOTOR) ".
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace cooling motor. Refer to "EXPLODED VIEW ".