CONSULT Reference Value in Data Monitor Mode
Specification data are reference values.
| Monitor item |
Condition |
Specification |
| ACCEL SEN 1 |
Ignition switch: ON (Engine stopped) |
Accelerator pedal: Fully released |
0.6 - 0.9 V |
| Accelerator pedal: Fully depressed |
4.0 - 4.8 V |
| ACCEL SEN 2 |
Ignition switch: ON (Engine stopped) |
Accelerator pedal: Fully released |
0.6 - 0.9 V |
| Accelerator pedal: Fully depressed |
3.9 - 4.8 V |
| CLSD THL POS |
Ignition switch: ON (Engine stopped) |
Accelerator pedal: Fully released |
ON |
| Accelerator pedal: Slightly depressed |
OFF |