Interior Room Lamp Control Does Not Operate

  1. CHECK EACH SWITCH

    Select "BCM" on CONSULT. With "INT LAMP" data monitor, make sure switches listed in display item list turn ON-OFF linked with switch operation. Refer to , "CONSULT FUNCTION (BCM) " for switches and their functions.

    OK or NG 

    OK: GO TO 2.

    NG: Inspect malfunctioning switch system.

  2. ACTIVE TEST
    1. Select "BCM" on CONSULT. Select "INT LAMP" active test.
    2. When room lamp switch is in DOOR position, make sure room lamp operates.

      Room lamp should operate  .

      OK or NG 

      OK: Replace BCM. Refer to , "REMOVAL AND INSTALLATION OF BCM ".

      NG: GO TO 3.

  3. CHECK ROOM LAMP INPUT VOLTAGE
    1. Turn ignition switch OFF.
    2. Check voltage between interior room lamp harness connector R5 terminal 2 and ground.

      2 - Ground: Battery voltage should exist  .

      Fig 1: Checking Room Lamp Input Voltage
      G04928383Courtesy of NISSAN NORTH AMERICA, INC.

      OK or NG 

      OK: GO TO 4.

      NG: GO TO  5.

  4. CHECK ROOM LAMP
    1. Disconnect room lamp connector.
    2. Check continuity between room lamp terminals.
      Room lamp Condition Continuity
      Terminal
      1 2 Room lamp switch is in DOOR position Yes
      Room lamp switch is in OFF position No
      Fig 2: Checking Room Lamp
      G04928384Courtesy of NISSAN NORTH AMERICA, INC.

      OK or NG 

      OK: GO TO  6.

      NG: Check bulb. If OK, replace room lamp. Refer to , "REMOVAL AND INSTALLATION ".

  5. CHECK ROOM LAMP CIRCUIT
    1. Disconnect BCM and interior room lamp connectors.
    2. Check continuity between BCM harness connector M20 (A) terminal 56 and room lamp harness connector R5 (B) terminal 2.

      56 - 2: Continuity should exist  .

      Fig 3: Checking Room Lamp Circuit
      G04928385Courtesy of NISSAN NORTH AMERICA, INC.

      OK or NG 

      OK: GO TO 6.

      NG: Repair harness or connector.

  6. CHECK ROOM LAMP CIRCUIT
    1. Disconnect BCM connector.
    2. Check continuity between BCM harness connector M20 (A) terminal 63 and room lamp harness connector R5 (B) terminal 1.

      63 - 1: Continuity should exist  .

      Fig 4: Checking Room Lamp Circuit
      G04928386Courtesy of NISSAN NORTH AMERICA, INC.

      OK or NG 

      OK: Replace BCM if interior lamp does not work after setting the connector again. Refer to , "REMOVAL AND INSTALLATION OF BCM ".

      NG: Repair harness or connector.