Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
- CHECK APP SENSOR 1 POWER SUPPLY CIRCUIT
- Disconnect accelerator pedal position (APP) sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between APP sensor harness connector and ground.
APP sensor Ground Voltage Connector Terminal E110 4 Ground Approx. 5 V Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair open circuit or short to ground or shot to power in harness or connectors.
- CHECK APP SENSOR 2 POWER SUPPLY CIRCUIT-I
- Check the voltage between APP sensor harness connector and ground.
APP sensor Ground Voltage Connector Terminal E110 5 Ground Approx. 5 V Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 4.
- Check the voltage between APP sensor harness connector and ground.
- CHECK APP SENSOR 2 POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between APP sensor harness connector and ECM harness connector.
APP sensor ECM Continuity Connector Terminal Connector Terminal E110 4 E16 106 Existed Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair open circuit or short to ground or shot to power in harness or connectors.
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
ECM Sensor Connector Terminal Name Connector Terminal F8 69 Tumble control valve actuator F22 1 71 Battery current sensor F53 1 74 Refrigerant pressure sensor E49 3 75 CKP sensor (POS) F20 1 76 EVAP control system pressure sensor B21 3 E16 102 APP sensor E110 5 Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to "DIAGNOSIS PROCEDURE ".)
- Tumble control valve (Refer to
"COMPONENT INSPECTION ".)
Is the inspection result normal?
YES >> GO TO 11.
NO >> Replace malfunctioning component.
- CHECK APP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between APP sensor harness connector and ECM harness connector as per the following.
APP sensor ECM Continuity Connector Terminal Connector Terminal E110 2 E16 111 Existed 1 104 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair open circuit or short to ground or shot to power in harness or connectors.
- CHECK APP SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between APP sensor harness connector and ECM harness connector as per the following.
APP sensor ECM Continuity Connector Terminal Connector Terminal E110 3 E16 110 Existed 6 103 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 9.
NO >> Repair open circuit or short to ground or shot to power in harness or connectors.
- Check the continuity between APP sensor harness connector and ECM harness connector as per the following.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES >> GO TO 11.
NO >> GO TO 10.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
Replace accelerator pedal assembly. Refer to "REMOVAL AND INSTALLATION ".
>> INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
>> INSPECTION END