Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
- CHECK TUMBLE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT-I
- Reconnect ECM harness connector disconnected.
- Turn ignition switch ON.
- Check the voltage between tumble control valve actuator harness connector and ground.
Tumble control valve actuator Ground Voltage Connector Terminal F22 1 Ground Approx. 5 V Is the inspection result normal?
YES >> GO TO 8.
NO >> GO TO 3.
- CHECK TUMBLE CONTROL VALVE POSITION SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between tumble control valve actuator harness connector and ECM harness connector.
Tumble control valve actuator ECM Continuity Connector Terminal Connector Terminal F22 1 F8 69 Existed Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair open circuit.
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
ECM Sensor Connector Terminal Name Connector Terminal F8 69 Tumble control valve actuator F22 1 71 Battery current sensor F53 1 74 Refrigerant pressure sensor E49 3 75 CKP sensor (POS) F20 1 76 EVAP control system pressure sensor B21 3 E16 102 APP sensor E110 5 Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENT
Check the following.
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to "DIAGNOSIS PROCEDURE ".)
- Tumble control valve (Refer to
"COMPONENT INSPECTION ".)
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace malfunctioning components.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES >> GO TO 10.
NO >> GO TO 7.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
Replace accelerator pedal assembly. Refer to "REMOVAL AND INSTALLATION ".
>> INSPECTION END
- CHECK TUMBLE CONTROL VALVE POSITION SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between tumble control valve actuator harness connector and ECM harness connector.
Tumble control valve actuator ECM Continuity Connector Terminal Connector Terminal F22 2 F8 47 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 9.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK TUMBLE CONTROL VALVE POSITION SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between tumble control valve actuator harness connector and ECM harness connector.
Tumble control valve actuator ECM Continuity Connector Terminal Connector Terminal F22 3 F8 35 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 10.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between tumble control valve actuator harness connector and ECM harness connector.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES >> Replace intake manifold adapter. Refer to "EXPLODED VIEW ".
NO >> Repair or replace harness or connectors.