LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2011 >> Versa Base, Automatic >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting System & Charging System >> Service Information >> Starter >> System Description >> CVT Models

CVT Models

Power is supplied at all times

With the ignition switch in the START position, power is supplied

With the selector lever in the P or N position, power is supplied

Ground is supplied at all times

If the IPDM E/R receives a starter relay request ON signal from the BCM over the CAN network, the IPDM E/R grounds the starter relay and power is supplied

The starter motor magnetic switch energizes closing the circuit between the battery and the starter motor. The starter motor is case ground through the cylinder block. With power and ground supplied, the starter motor operates.