Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E21. Refer to Ground Inspection in " CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: Go to 2.
NO: Repair or replace ground connection.
- CHECK INTAKE AIR TEMPERATURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Go to 3.
NO: Replace mass air flow sensor (with intake air temperature sensor). Refer to " REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to " INTERMITTENT INCIDENT ".
INSPECTION END