Diagnosis Procedure
- PERFORM INITIALIZATION
- Perform initialization with CONSULT-III. Reregister all mechanical keys. Refer to "CONSULT-III Operation Manual NATS-IVIS/NVIS".
- Start the engine.
Dose the engine start?
YES: INSPECTION END
NO: GO TO 2.
- CHECK DONGLE UNIT CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and dongle unit connector.
- Check continuity between BCM harness connector and dongle unit harness connector.CONTINUITY SPECIFICATION
BCM Dongle unit Continuity Connector Terminal Connector Terminal M68 24 M75 7 Existed - Check continuity between BCM harness connector and ground.
CONTINUITY SPECIFICATIONBCM Ground Continuity Connector Terminal M68 24 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness.
- CHECK DONGLE UNIT GROUND CIRCUIT
Check continuity between dongle unit harness connector and ground.
CONTINUITY SPECIFICATIONDongle unit Ground Continuity Connector Terminal M75 1 Existed Is the inspection result normal?
YES: Replace dongle unit.