Knock Sensor
- Check resistance between knock sensor terminal 1 and ground.NOTE: It is necessary to use an ohmmeter which can measure more than 10 MΩ.
Resistance: Approximately 532 - 588kΩ [at 20°C (68°F)]
CAUTION: Do not use any knock sensors that have been dropped or physically damaged. Use only new ones. - If NG, replace knock sensor.