LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2008 >> Sentra SE-R >> Repair and Diagnosis >> Electrical >> Gauges >> Driver Information System >> Warning Chime >> Parking Brake Switch Signal Inspection

Parking Brake Switch Signal Inspection

  1. CHECK PARKING BRAKE SWITCH SIGNAL INPUT (COMBINATION METER) 
    1. Turn ignition switch ON.
    2. Check voltage between combination meter harness connector M24 terminal 24 and ground.
      CONNECTOR TERMINAL VOLTAGE SPECIFICATION

      Terminals Condition Voltage (Approx.)
      (+) (-)
      Combination meter connector Terminal
      M24 24 Ground Parking brake released Battery voltage
      Parking brake applied 0
      Fig 1: Checking Voltage Between Combination Meter Harness Connector M24 Terminal 24 And Ground
      G04928469Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: Replace combination meter. Refer to "COMBINATION METER ".

    NG: GO TO 2.

  2. CHECK PARKING BRAKE SWITCH CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect combination meter connector and parking brake switch connector.
    3. Check continuity between combination meter harness connector (A) and parking brake switch harness connector (B).
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A B Continuity
      Connector Terminal Connector Terminal
      M24 24 B24 1 Yes
    4. Check continuity between combination meter harness connector (A) and ground.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      A Ground Continuity
      Connector Terminal
      M24 24 No

    OK or NG 

    OK: GO TO 3.

    NG: Repair harness or connector.

    Fig 2: Checking Continuity Between Combination Meter Harness Connector And Parking Brake Switch Harness Connector
    G04928470Courtesy of NISSAN MOTOR CO., U.S.A.
  3. CHECK PARKING BRAKE SWITCH 

    Check parking brake switch. Refer to "PARKING BRAKE SWITCH ".

    OK or NG 

    OK: Check parking brake switch case ground.

    NG: Replace parking brake switch.