Front Door Switch LH Signal Inspection
- CHECK BCM INPUT SIGNAL
With CONSULT-III
- Select "BCM".
- With "DATA MONITOR" of "BUZZER", confirm "DOOR SW-DR" when the driver's door is operated.
"DOOR SW-DR"
When driver's door is opened : ON
When driver's door is closed : OFF
Without CONSULT-III
Check voltage between BCM harness connector and ground.
CONNECTOR TERMINAL VOLTAGE SPECIFICATIONTerminals Condition Voltage (Approx.) (+) (-) BCM connector Terminal M19 47 Ground Driver's door is opened 0 Driver's door is closed Battery voltage OK or NG
OK: Front door switch LH signal is OK. Return to "SYMPTOM CHART ".
NG: GO TO 2.
- CHECK FRONT DOOR SWITCH LH CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and front door switch LH connector.
- Check continuity between BCM harness connector (A) and front door switch LH harness connector (B).CONNECTOR TERMINAL CONTINUITY SPECIFICATION
A B Continuity Connector Terminal Connector Terminal M19 47 B21 2 Yes - Check continuity between BCM harness connector (A) and ground.CONNECTOR TERMINAL CONTINUITY SPECIFICATION
A Ground Continuity Connector Terminal M19 47 No
OK or NG
OK: GO TO 3.
NG: Repair harness or connector.
- CHECK FRONT DOOR SWITCH LH
Check front door switch LH. Refer to "FRONT DOOR SWITCH LH ".
OK or NG
OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".
NG: Replace front door switch LH.