Diagnosis Procedure
- CHECK GROUND CONNECTIONS
- Turn ignition switch OFF.
- Loosen and retighten two ground screws on the body. Refer to "GROUND INSPECTION ".
OK or NG
OK : GO TO 2.
NG : Repair or replace ground connections.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor (2) harness connector.
- EVAP canister vent control valve (1)
- Drain filter (3)
- EVAP canister (4)
<=: Vehicle front
- Check sensor harness connector for water.
Courtesy of NISSAN MOTOR CO., U.S.A.
Water should not exist .
OK or NG
OK : GO TO 3.
NG : Repair or replace harness connector.
- Disconnect EVAP control system pressure sensor (2) harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-III or tester.
Voltage: Approximately 5V
OK or NG
OK : GO TO 5.
NG : GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal 67.
Refer to WIRING DIAGRAM .
Continuity should exist .
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 7.
NG : GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal 2.
Refer to WIRING DIAGRAM .
Continuity should exist .
- Also check harness for short to ground and short to power.
OK or NG
OK : GO TO 9.
NG : GO TO 8.
- Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
OK or NG
OK : GO TO 10.
NG : Replace EVAP control system pressure sensor.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END