Inspection Procedure

WARNING: This page is about a different car, the 2006 Nissan Sentra. However, it is still accessible from the selected car via links, so may be relevant.

If the CONSULT-II cannot diagnose the system properly, check the following items.

CONSULT-II SYMPTOM CHECK CHART

Symptom Check item
CONSULT-II cannot access any system.
  • CONSULT-II DLC power supply circuit (Terminal 8) and ground circuit (Terminal 4) (For detailed circuit, refer to "WIRING DIAGRAM " (QG18DE) or "WIRING DIAGRAM " (QR25DE).
  • CONSULT-II DLC cable and CONSULT-II CONVERTER.
CONSULT-II cannot access individual system. (Other systems can be accessed.)
  • CONSULT-II program card (Check the appropriate CONSULT-II program card for the system. Refer to "Checking Equipment ".)
  • Power supply and ground circuit for the control unit of the system (For detailed circuit, refer to wiring diagram for each system.)
  • Open or short circuit in CAN or K communication line.
NOTE: The preceding schematic is an example and may not be a true representation of the vehicle. The actual DDL1 circuits (CAN lines) from DLC pins 6 and 14 as well as the DDL2 circuit (K-line) from DLC pin 7 may be connected to more than one system. A short in a DDL circuit connected to a control unit in one system may affect CONSULT-II access to other systems.