Inspection Procedure
- SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
SELF-DIAGNOSIS RESULTSSelf-diagnosis results STOP LAMP SW Is the above displayed in the self-diagnosis display items?
Yes: GO TO 2.
NO: Inspection End.
- CONNECTOR INSPECTION
- Disconnect the ABS actuator and electric unit (control unit) connector E125 and stop lamp switch connector E38.
- Check the terminals for deformation, disconnection, looseness or damage.
OK or NG
OK: GO TO 3.
NG: Repair or replace as necessary.
- STOP LAMP SWITCH INSPECTION
Turn the ignition switch ON and check the voltage between the ABS actuator and electric unit (control unit) connector E125 terminal 8 and ground.
8 - Ground
Brake pedal depressed : Battery voltage (approx. 12V)
Brake pedal not depressed : Approx. 0V
OK or NG
OK: Perform self-diagnosis again. If the same results appear, replace ABS actuator and electric unit (control unit). Refer to "REMOVAL AND INSTALLATION ".
NG: Repair the circuit.