Procedure For Malfunction A
- CHECK GROUND CONNECTIONS
- Turn ignition switch OFF.
- Loosen and retighten two ground screws on the body.
Refer to , "GROUND INSPECTION ".
OK or NG
OK: GO TO 2.
NG: Repair or replace ground connections.
- CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Disconnect heated oxygen sensor 2 harness connector.
- Check harness continuity between HO2S2 terminal 4 and ECM terminal 78.
Refer to WIRING DIAGRAM.
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 3.
NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to WIRING DIAGRAM.
TERMINALS CONTINUITY CHARTDTC Terminals Bank ECM Sensor P0138 74 1 1 P0158 55 1 2 Continuity should exist.
- Check harness continuity between the following terminals and ground.
Refer to WIRING DIAGRAM.
TERMINALS CONTINUITY CHARTDTC Terminals Bank ECM Sensor P0138 74 1 1 P0158 55 1 2 Continuity should not exist.
- Also check harness for short to power.
OK or NG
OK: GO TO 4.
NG: Repair open circuit or short to ground or short to power in harness or connectors.
- Check harness continuity between ECM terminal and HO2S2 terminal as follows.
- CHECK HO2S2 CONNECTOR FOR WATER
Check connectors for water.
Water should not exist.
OK or NG
OK: GO TO 5.
NG: Repair or replace harness or connectors.
- CHECK HEATED OXYGEN SENSOR 2
Refer to , "COMPONENT INSPECTION ".
OK or NG
OK: GO TO 6.
NG: Replace malfunctioning heated oxygen sensor 2.
- CHECK INTERMITTENT INCIDENT
Refer to , "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".
: INSPECTION END