Ignition Signal: Wiring Diagram
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) |
|---|---|---|---|---|
| 111 | BR | ECM relay (Self shut-off) |
[Engine is running] [Ignition switch: OFF]
|
0-1.5V |
[Ignition switch: OFF]
|
BATTERY VOLTAGE (11 -14V) | |||
| 119 120 | R P | Power supply for ECM | [Ignition switch: ON] | BATTERY VOLTAGE (11 -14V) |
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground. Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) | ||
|---|---|---|---|---|---|---|
| 60 61 62 |
SB L Y |
Ignition signal No. 5 Ignition signal No. 3 Ignition signal No. 1 |
[Engine is running]
NOTE:
The pulse cycle changes depending on RPM at idle
|
0 - 0.2V(1) | ||
[Engine is running]
|
0.1 -0.4V(1) | |||||
|
||||||
For PG Power or Section, go to SYSTEM WIRING DIAGRAMS .
Specification data are reference values and are measured between each terminal and ground. Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
ECM GROUND TERMINALS INPUT/OUTPUT VOLTAGE REFERENCE
| TERMINAL NO. | WIRE COLOR | ITEM | CONDITION | DATA (DC Voltage) | ||
|---|---|---|---|---|---|---|
| 79 80 81 |
P GR G |
Ignition signal No. 6 Ignition signal No. 4 Ignition signal No. 2 |
[Engine is running]
NOTE:
The pulse cycle changes depending on RPM at idle
|
0 - 0.2V(1) | ||
[Engine is running]
|
0.1 -0.4V(1) | |||||
|
||||||