| None of the power windows can be operated using any switch |
1. BCM POWER SUPPLY AND GROUND CIRCUIT CHECK |
| 2. MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SUPPLY AND GROUND CIRCUIT CHECK |
| 3. POWER WINDOW SERIAL LINK CHECK |
| Front power window LH alone does not operate |
1. FRONT POWER WINDOW MOTOR LH CIRCUIT CHECK |
| 2. Replace main power window and door lock/unlock switch |
| Front power window RH alone does not operate |
1. POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH POWER AND GROUND CIRCUIT CHECK |
| 2. POWER WINDOW SERIAL LINK CHECK |
| 3. FRONT POWER WINDOW MOTOR RH CIRCUIT CHECK |
| 4. Replace BCM |
| Rear power vent window LH alone does not operate |
1. REAR POWER VENT WINDOW MOTOR LH CIRCUIT CHECK |
| Rear power vent window RH alone does not operate |
1. REAR POWER VENT WINDOW MOTOR RH CIRCUIT CHECK |
| Anti-pinch system does not operate normally (Front LH) |
1. Door window sliding part malfunction
- A foreign material adheres to window glass or glass run rubber.
- Glass run rubber wear or deformation.
- Sash is tilted too much, or not enough.
|
| 2. LIMIT SWITCH ADJUSTING |
| 3. LIMIT SWITCH CIRCUIT CHECK LH |
| 4. ENCODER CIRCUIT CHECK LH |
| Anti-pinch system does not operate normally (Front RH) |
1. Door window sliding part malfunction
- A foreign material adheres to window glass or glass run rubber.
- Glass run rubber wear or deformation.
- Sash is tilted too much, or not enough.
|
| 2. LIMIT SWITCH ADJUSTING |
| 3. LIMIT SWITCH CIRCUIT CHECK RH |
| 4. ENCODER CIRCUIT CHECK RH |
| Power window retained power operation does not operate properly |
1. CHECK THE RETAINED POWER OPERATION MODE SETTING. |
| 2. DOOR SWITCH CHECK |
| 3. Replace BCM. |
| Front power windows do not operate by front door lock assembly LH (key cylinder switch) |
1. FRONT DOOR LOCK ASSEMBLY LH (KEY CYLINDER SWITCH) CHECK |
| 2. Replace main power window and door lock/unlock switch |
| Power window lock switch does not function |
1. POWER WINDOW LOCK SWITCH CIRCUIT CHECK |