Inspection Procedure
- CHECK SELF-DIAGNOSIS RESULT
With CONSULT-II
- Turn ignition switch "ON". (Do not start engine.)
- Select "SELF-DIAG RESULTS" mode for "ABS" with CONSULT-II.
- Touch "ERASE".
- Turn ignition switch "OFF" and wait at least 10 seconds.
- Check the self-diagnostic results.
RESULT CHARTSelf-diagnosis results G-SENSOR Is above displayed in the self-diagnosis display?
YES: GO TO 2.
NO: INSPECTION END
- CHECK G SENSOR
Use "Data Monitor" to check if the G sensor are normal.
VEHICLE STATUS CHARTVehicle status G sensor (Data monitor standard) When stopped -0.11 G to + 0.11 G Speed up Negative value OK or NG
OK: INSPECTION END
NG: Replace ABS actuator and electric unit (control unit) and then perform ABS actuator and electric unit (control unit) self-diagnosis again.