LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2005 >> Sentra SE-R >> Repair and Diagnosis >> External Pages >> Different car >> Section 18 (Body, Lock & Security System) >> Power Door Lock System >> Door Lock and Unlock Switch Check

Door Lock and Unlock Switch Check

WARNING: This page is about a different car, the 2007 Nissan Sentra. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK DOOR LOCK AND UNLOCK INPUT SIGNAL 

    With CONSULT-III 

    Check door lock and unlock switch ("CDL LOCK SW" and "CDL UNLOCK SW") in DATA MONITOR mode with CONSULT-III.

    DATA MONITOR MODE

    Test item Condition
    CDL LOCK SW Door lock and unlock switch is turned to LOCK : ON
    Other than above : OFF
    CDL UNLOCK SW Door lock and unlock switch is turned to UNLOCK : ON
    Other than above : OFF

    Without CONSULT-III 

    Check voltage between BCM connector and ground

    BCM CONNECTOR TERMINAL VOLTAGE SPECIFICATION

    Terminals Door lock and unlock switch condition Voltage (V) (Approx.)
    (+) (-)
    BCM connector Terminal
    M19 45 Ground Lock 0
    Neutral / Unlock Battery voltage
    46 Unlock 0
    Neutral / Lock Battery voltage

    OK or NG 

    OK: Door lock and unlock switch is OK.

    NG1: With power windows, GO TO 2.

    NG2: Without power windows, GO TO  5.

    Fig 1: Checking Voltage Between BCM Connector And Ground
    G04927564
  2. CHECK DOOR LOCK/UNLOCK SWITCH 
    1. Turn ignition switch OFF.
    2. Disconnect door lock/unlock switch.
    3. Check continuity between main power window and door lock/unlock switch terminals 10, 11 and 14.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      Terminals Condition Continuity
      10 14 Lock Yes
      Unlock/Neutral No
      11 Unlock Yes
      Lock/Neutral No
    4. Check continuity between power window and door lock/unlock switch RH terminals 1, 2 and 3.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      Terminals Condition Continuity
      1 3 Lock Yes
      Unlock/Neutral No
      2 Unlock Yes
      Lock/Neutral No
      Fig 2: Checking Continuity Between Power Window And Door Lock/Unlock Switch RH Terminals 1, 2 And 3
      G04895673

    OK or NG 

    OK: GO TO 3.

    NG: Replace door lock/unlock switch.

  3. CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS 
    1. Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch RH.
    2. Check continuity between main power window and door lock/unlock switch connector D5 terminal 14 and ground.

      14 - Ground : Continuity should exist. 

      Fig 3: Checking Continuity Between Door Lock/Unlock Switch Connector D5 Terminal 14 And Ground
      G04895674
    3. Check continuity between power window and door lock/unlock switch RH connector D104 terminal 3 and ground

      3 - Ground : Continuity should exist. 

    OK or NG 

    OK: GO TO 4.

    NG: Repair or replace harness.

    Fig 4: Checking Continuity Between Power Window And Door Lock/Unlock Switch RH Connector D104 Terminal 3 And Ground
    G04895675
  4. CHECK DOOR LOCK SWITCH CIRCUIT 
    1. Disconnect BCM.
    2. Check continuity between BCM connector M19 terminal 45 and main power window and door lock/unlock switch connector D5 terminal 10 or power window and door lock/unlock switch RH connector D104 terminal 1.

      1 - 45 : Continuity should exist. 

      10 - 45 : Continuity should exist. 

    3. Check continuity between BCM connector M19 terminal 45 and ground.

      45 - Ground : Continuity should not exist. 

      Fig 5: Checking Continuity Between BCM Connector M19 Terminal 45 And Ground
      G04895676
    4. Check continuity between BCM connector M19 terminal 46 and main power window and door lock/unlock switch LH connector D5 terminal 11 or power window and door lock/unlock switch RH connector D104 terminal 2.

      2 - 46 : Continuity should exist. 

      11 - 46 : Continuity should exist. 

    5. Check continuity between BCM connector M19 terminal 46 and ground.

      46 - Ground : Continuity should not exist. 

    OK or NG 

    OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".

    NG: Repair or replace harness.

    Fig 6: Checking Continuity Between BCM Connector M19 Terminal 46 And Ground
    G04895677
  5. CHECK DOOR LOCK/UNLOCK SWITCH LH 
    1. Turn ignition switch OFF.
    2. Disconnect door lock/unlock switch LH.
    3. Check continuity between door lock/unlock switch LH terminals 1, 2 and 5.
      CONNECTOR TERMINAL CONTINUITY SPECIFICATION

      Terminals Condition Continuity
      1 5 Lock Yes
      Unlock/Neutral No
      2 Unlock Yes
      Lock/Neutral No

    OK or NG 

    OK: GO TO 6.

    NG: Replace door lock/unlock switch LH.

    Fig 7: Checking Continuity Between Door Lock/Unlock Switch LH Terminals 1, 2 And 5
    G04927570
  6. CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS 

    Check continuity between door lock/unlock switch connector D6 terminal 5 and ground.

    5 - Ground : Continuity should exist. 

    OK or NG 

    OK: GO TO 7.

    NG: Repair or replace harness.

    Fig 8: Checking Continuity Between Door Lock/Unlock Switch Connector D6 Terminal 5 And Ground
    G04927571
  7. CHECK DOOR LOCK SWITCH CIRCUIT 
    1. Disconnect BCM.
    2. Check continuity between BCM connector M19 (A) terminal 45 and door lock/unlock switch LH connector D6 (B) terminal 1.

      1 - 45 : Continuity should exist. 

    3. Check continuity between BCM connector M19 (A) terminal 45 and ground.

      45 - Ground : Continuity should not exist. 

      Fig 9: Checking Continuity Between BCM Connector M19 Terminal 45 And Ground
      G04927572
    4. Check continuity between BCM connector M19 (A) terminal 46 and door lock/unlock switch LH connector D6 (B) terminal 2.

      2 - 46 : Continuity should exist. 

    5. Check continuity between BCM connector M19 (A) terminal 46 and ground.

      46 - Ground : Continuity should not exist. 

    OK or NG 

    OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".

    NG: Repair or replace harness.

    Fig 10: Checking Continuity Between BCM Connector M19 Terminal 46 And Ground
    G04927573