Horn Reminder Check
- CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
- Yes: GO TO 2.
- No: Check horn circuit.
- CHECK HORN REMINDER OPERATION
With CONSULT-II
- Select "ACTIVE TEST" in "MULTI REMOTE ENT" with CONSULT-II.
- Select "MULTI REM HRN" and touch "ON".
NOTE: If CONSULT-II is not available, skip this procedure and go to the next step.
OK or NG
- OK: Horn reminder operation is OK.
- NG: GO TO 3.
- CHECK HORN REMINDER OPERATION
- Disconnect smart entrance control unit harness connector.
- Apply ground to smart entrance control unit harness connector terminal 19.
Courtesy of NISSAN MOTOR CO., U.S.A.
Refer to "WIRING DIAGRAM - KEYLES - ".
Does horn sound?
- Yes: Replace smart entrance control unit.
- No: Check harness for open or short between smart entrance control unit and horn relay.