Description & Operation
Power is supplied at all times through 40A fusible link (letter M, located in the fuse and fusible link block) to ignition switch terminal No. 1 through 15A fuse (No. 73, located in the IPDM E/R) to CPU of IPDM E/R.
With the ignition switch in the "ON" or "START" position, power is supplied through 10A fuse (No. 80, located in the IPDM E/R) to CPU of IPDM E/R.
When the selector lever in the "P" or "N" position, power is supplied from A/T assembly (TCM) terminal No. 24 to IPDM E/R terminal No. 43. Ground is supplied to IPDM E/R terminals No. 14, 45 and 46 from body grounds E13 and E28. Then starter relay is turned ON.
With the ignition switch in the "START" position, IPDM E/R is energized and power is supplied from ignition switch terminal No. 5 to IPDM E/R terminal No. 11 and through IPDM E/R terminal No. 4 to starter motor terminal No. 1.
The starter motor plunger closes and provides a closed circuit between the battery and starter motor. The starter motor is grounded to the engine block. With power and ground supplied, cranking occurs and the engine starts.