LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Sentra SE-R >> Repair and Diagnosis >> External Pages >> Different car >> Section 1965 (Starting System - Sedan) >> Battery >> How to Handle Battery >> Specific Gravity Check >> Hydrometer Temperature Correction

Hydrometer Temperature Correction

WARNING: This page is about a different car, the 2005 Infiniti G35. However, it is still accessible from the selected car via links, so may be relevant.
BATTERY ELECTROLYTE TEMPERATURE SPECIFICATION

Battery electrolyte temperature °C (°F) Add to specific gravity reading
71 (160) 0.032
66 (150) 0.028
60 (140) 0.024
54 (130) 0.020
49 (120) 0.016
43 (110) 0.012
38 (100) 0.008
32 (90) 0.004
27 (80) 0
21 (70) -0.004
BATTERY ELECTROLYTE TEMPERATURE SPECIFICATION

Battery electrolyte temperature °C (°F) Add to specific gravity reading
16 (60) -0.008
10 (50) -0.012
4 (40) -0.016
-1 (30) -0.020
-7 (20) -0.024
-12 (10) -0.028
-18 (0) -0.032
CORRECTED SPECIFIC GRAVITY REFERENCE

Corrected specific gravity Approximate charge condition
1.260 - 1.280 Fully charged
1.230 - 1.250 3/4 charged
1.200 - 1.220 1/2 charged
1.170 - 1.190 1/4 charged
1.140 - 1.160 Almost discharged
1.110 - 1.130 Completely discharged