HYDROMETER TEMPERATURE CORRECTION

Battery electrolyte temperature °C (°F) Add to specific gravity reading
71 (160) 0.032
66(150) 0.028
60(140) 0.024
54(130) 0.020
49(120) 0.016
43(110) 0.012
38 (100) 0.008
32 (90) 0.004
27 (80) 0
21 (70) -0.004
16(60) -0.008
10 (50) -0.012
4 (40) -0.016
-1 (30) -0.020
-7 (20) -0.024
-12(10) -0.028
-18(0) -0.032
ADJUSTED APPROXIMATE CHARGE CONDITION

Corrected specific gravity Approximate charge condition
1.260-1.280 Fully charged
1.230 - 1.250 3/4 charged
1.200 - 1.220 1/2 charged
1.170 - 1.190 1 /4 charged
1.140-1.160 Almost discharged
1.110-1.130 Completely discharged