Manual Operation: Notes
Front Door LH
Ground is supplied
- to power window main switch terminal 17
- through body grounds M4, M66, M111, M147 and M157.
WINDOW UP
When the front LH switch in the power window main switch is pressed in the up position, power is supplied
- to front power window motor LH terminal 1
- through power window main switch terminal 8.
Ground is supplied
- to front power window motor LH terminal 3
- through power window main switch terminal 11
Then, the motor raises the window until the switch is released.
WINDOW DOWN
When the LH switch in the power window main switch is pressed in the down position, power is supplied
- to front power window motor LH terminal 3
- through power window main switch terminal 11.
Ground is supplied
- to front power window motor LH terminal 1
- through power window main switch terminal 8.
Then, the motor lowers the window until the switch is released.