2. Check EGR Volume Control Valve Power Supply Circuit
- Turn ignition switch OFF.
- Disconnect EGR volume control valve harness connector.
- Turn ignition switch ON.
- Check voltage between EGR volume control valve terminals 2, 5 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
- OK: GO TO 4 .
- NG: GO TO 3.