With CONSULT-II
- Turn ignition switch ON.
- Select "DATA MONITOR" mode with CONSULT-II.
- Wait at least 6 seconds.
- If DTC is detected, go to 7 under "DIAGNOSTIC PROCEDURE".
If DTC is not detected, go to next step.
- Start engine and let it idle for at least 6 seconds.
- If DTC is detected, go to DIAGNOSTIC PROCEDURE .