Diagnostic Procedure
WARNING: This page is about a different car, the 2007 Nissan Quest. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK PNP SWITCH CIRCUIT
With CONSULT-II
- Turn ignition switch "ON". (Do not start engine.)
- Select "DATA MONITOR" mode for "TRANSMISSION" with CONSULT-II.
- Move selector lever to "P""R""N""D" and "L" position and check the value of "PNP SW A""PNP SW B""PNP SW C""PNP SW PA" and "PNP SW PN".PNP SWITCH CHART
Selector lever "PNP SW A" "PNP SW B" "PNP SW C" "PNP SW PA" "PNP SW PN" P ON OFF OFF ON ON R ON ON OFF OFF OFF N OFF ON OFF ON ON D OFF ON ON OFF OFF L ON ON ON ON OFF
Without CONSULT-II
- Turn ignition switch "ON". (Do not start engine.)
- Move selector lever to "P""R""N""D" and "L" position and check voltage between the TCM connector terminals and ground.CONNECTOR TERMINAL CHART
Selector lever Connector No. E142 Terminal 24 - Ground 31 - Ground 32 - Ground 33 - Ground 43 - Ground P 0V Battery voltage Battery voltage Battery voltage 0V R 0V 0V Battery voltage 0V Battery voltage N Battery voltage 0V Battery voltage Battery voltage 0V D Battery voltage 0V 0V 0V Battery voltage L 0V 0V 0V 0V 0V
OK or NG
OK: GO TO 5.
NG: GO TO 2.
- CHECK PNP SWITCH POWER SOURCE CIRCUIT
- Turn ignition switch "OFF".
- Disconnect the PNP switch connector.
- Turn ignition switch "ON". (Do not start engine.)
- Check the voltage between PNP switch connector terminal 1 and ground.VOLTAGE CHART
Connector Terminal Voltage F29 1 - Ground Battery voltage - Turn ignition switch "OFF".
- Check voltage between PNP switch connector terminal 1 and ground.VOLTAGE CHART
Connector Terminal Voltage F29 1 - Ground 0V - If OK, check harness for short-circuit to ground or power source.
OK or NG
OK: GO TO 3.
NG: Check the following. If any items are damaged, repair or replace damaged parts.
- Harness for short or open between ignition switch and PNP switch
- Ignition switch and fuse
Refer to "POWER SUPPLY ROUTING CIRCUIT ".
- CHECK HARNESS BETWEEN TCM AND PNP SWITCH
- Turn ignition switch "OFF".
- Disconnect the TCM connector and PNP switch connector.
- Check continuity between TCM connector terminals 24, 31, 32, 43 and ground.CONTINUITY CHART
Connector Terminal Condition Continuity E142 24 - Ground Selector lever: "P""R" and "L" position Yes Other than the above No 31 - Ground Selector lever: "R""N""D" and "L" position Yes Other than the above No 32 - Ground Selector lever: "D" and "L" position Yes Other than the above No 43 - Ground Selector lever: "P""N" and "L" position Yes Other than the above No - If OK, check the following.
- Harness for short-circuit to ground or power source.
- Open or short-circuit in the harness between combination meter and TCM.
OK or NG
OK: GO TO 5.
NG: GO TO 4.
- DETECT MALFUNCTIONING ITEM
Check the following.
- Open or short-circuit in the harness between TCM and PNP switch A, B, C, PA.
- Open or short-circuit in the harness for ground of PNP switch.
- PNP switch. Refer to "COMPONENT INSPECTION ".
OK or NG
OK: GO TO 6.
NG: Repair or replace damaged parts.
- CHECK DTC
Perform "DTC Confirmation Procedure". Refer to "DTC CONFIRMATION PROCEDURE ".
OK or NG
OK: INSPECTION END
NG: GO TO 6.
- CHECK TCM
- Check TCM input/output signal. Refer to "TCM INPUT/OUTPUT SIGNAL REFERENCE VALUES ".
- If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK: INSPECTION END
NG: Repair or replace damaged parts.