DTC Confirmation Test
Malfunction is detected when proper pulse signal from Intake Valve Timing Control (IVTC) position sensor if not received from ECM while engine is running at specified speed. Possible causes are:
- IVTC position sensor circuit open or shorted.
- Defective IVTC position sensor.
- Accumulation of debris on signal pick-up portion of camshaft.
To set DTC, turn ignition on. Select DATA MONITOR with scan tool. Start engine and run at 2000 RPM for at least 15 seconds. If first trip DTC is detected, go to PROCEDURE .