Testing Speed Sensor Signal Check
Disconnect speedometer cable from instrument cluster. Remove combination meter. Insert a small screwdriver into speedometer cable hole behind speedometer. Using an ohmmeter, check continuity between specified terminals while slowly rotating sensor with screwdriver. See the SPEED SENSOR CONTINUITY CHECK table for terminal specifications. See Figure -2. While turning sensor, needle on ohmmeter should deflect twice per revolution.
SPEED SENSOR CONTINUITY CHECK
| Application | + Terminal | - Terminal |
|---|---|---|
| W/ Tachometer | 18 | 24 |