How to Check Enlarged Contact Spring of Terminal
- An enlarged contact spring of a terminal may create intermittent signals in the circuit.
- If the intermittent open circuit occurs, follow the procedure below to inspect for open wires and enlarged contact spring of female terminal.
- Assemble a male terminal and approx. 10 cm (3.9 in) of wire.NOTE: Use a male terminal which matches the female terminal.
- Disconnect the suspected faulty connector and hold it terminal side up.
- While holding the wire of the male terminal, try to insert the male terminal into the female terminal.CAUTION: Never force the male terminal into the female terminal with your hands.
- While moving the connector, check whether the male terminal can be easily inserted or not.
- Assemble a male terminal and approx. 10 cm (3.9 in) of wire.
- If the male terminal can be easily inserted into the female terminal, replace the female terminal.