Inspection Procedure
- CHECK 12V BATTERY TERMINALS CONNECTION
Check if 12V battery terminals are clean and tight.
Is the inspection result normal?
YES >>
GO TO 2.
NO >>
Repair 12V battery terminals connection.
- CHECK "B" TERMINAL CONNECTION
Check if "B" terminal (generator ground harness) is clean and tight.
Is the inspection result normal?
YES >>
GO TO 3.
NO >>
Repair "B" terminal connection.
- CHECK 12V BATTERY STATUS
Check 12V battery status. Refer to WORK FLOW .
Is the inspection result normal?
YES >>
GO TO 4.
NO >>
Replace 12V battery. Refer to REMOVAL AND INSTALLATION .
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to INSPECTION .
Is the inspection result normal?
YES >>
INSPECTION END
NO >>
Repair as needed.