DTC Confirmation Procedure
- PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
Do you have M.U.T.-III SE?
YES >>
GO TO 2.
NO >>
GO TO 4.
- PERFORM DTC CONFIRMATION PROCEDURE-1
WITH M.U.T.-III SE
- Turn ignition switch ON and select "EVAP DIAG READY" in "DATA MONITOR" mode of "ENGINE" using M.U.T.-III SE.
- Start engine and wait at idle until "OFF" of "EVAP DIAG READY" changes to "ON".NOTE: It will take at most 2 hours until "OFF" of "EVAP DIAG READY" changes to "ON".
- Turn ignition switch OFF and wait at least 90 minutes.NOTE: Never turn ignition switch ON during 90 minutes.
- Turn ignition switch ON and select "EVAP LEAK DIAG" in "DATA MONITOR" mode of "ENGINE" using M.U.T.-III SE.
- Check that "EVAP LEAK DIAG" indication.
Which is displayed on M.U.T.-III SE?
CMPLT >>
GO TO 3.
YET >>
Perform DTC CONFIRMATION PROCEDURE again.
GO TO 1.
- PERFORM DTC CONFIRMATION PROCEDURE-2
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>
Proceed to DTC DIAGNOSIS PROCEDURE
NO >>
INSPECTION END.
- PERFORM DTC CONFIRMATION PROCEDURE
WITH GST
- Start the engine and wait engine idle for at least 2 hours.
- Turn ignition switch OFF and wait at least 90 minutes.NOTE: Never turn ignition switch ON during 90 minutes.
- Turn ignition switch ON.
- Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>
Proceed to DTC DIAGNOSIS PROCEDURE .
NO-1 >>
To check malfunction symptom before repair: Refer to INTERMITTENT INCIDENT .
NO-2 >>
Confirmation after repair: INSPECTION END