Check Initial Learning Quantity: Procedure
- Confirm that the power supply mode of the electric motor switch is OFF, and connect the scan tool (M.U.T.-III SE).
- Turn the power supply mode of the electric motor switch to ON (READY indicator: OFF).
- Confirm that the value of data list item No. 180: "Movement Range Learned Value" is within the standard value.
Standard value: 319 - 516
- If the value is larger than the standard value, replace the front transaxle assembly.
- If the value is smaller than the standard value, carry out the troubleshooting for DTC No. P1C43-96: Encoder Failure.