Fluid Deterioration Level Erasing Procedure
- Move the selector lever to the "P" range and turn the ignition switch to the "LOCK" (OFF) position. Then, connect scan tool (M.U.T.-III) to the data link connector.
- Turn the ignition switch to the "ON" position.
- Use the scan tool (M.U.T.-III) special function to execute "CVT oil degradation level (item number 1: Clear CVT oil degradation level)".
- Turn the ignition switch to the "LOCK" (OFF) position, and then wait for 10 seconds.