LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2017 >> RVR ES, Standard Trans >> Repair and Diagnosis >> Electrical >> Gauges >> Combination Meter - With Diagnostics >> On-Vehicle Service >> Fuel Level Sensor Check >> Nominal Resistance Of The Fuel Level Sensor

Nominal Resistance Of The Fuel Level Sensor

  1. Remove the fuel pump module (Refer to ON-VEHICLE SERVICE < Main >).
  2. When float of the fuel level sensor is in stopper positions F and E, ensure that resistance between the fuel level sensor terminal and ground terminal is within the standard value.
    RESISTANCE SPECIFICATION

    Float position Gauge resistance value (ohms)
    Stopper position "F" 13.0 ± 1.0
    Stopper position "E" 120.0 ± 1.0
    RESISTANCE SPECIFICATION

    Float position Gauge resistance value (ohms)
    Main Sub
    Stopper position "F" 6.5 ± 1.0 6.5 ± 1.0
    Stopper position "E" 44.7 ± 1.0 75.3 ± 1.0
  3. When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.
    Fig 1: Checking Resistance Between Fuel Level Sensor And Ground Terminals
    G05906327Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.