Starter Relay Continuity Check
Battery voltage
Terminal number to be connected to tester
Continuity test results
Not applied
4 - 3
Open circuit
Connect terminal No. 1 and positive battery terminal.
Connect terminal No. 2 and negative battery terminal.
Continuity (less than 2 ohms)
Fig 1: Checking Starter Relay Continuity
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.