Rectifier Assembly
Use the analog type tester to make sure the electrical continuity of each diode meets the table specification.
Unless the electrical continuity of each diode meets the table specification, replace the rectifier.
DIODE CONTINUITY TABLE
| (-) side | (+) side | Electrical continuity |
|---|---|---|
| E | P1, P2, P3, P4, P5, P6 | Yes |
| B | No | |
| P1, P2, P3, P4, P5, P6 | E | No |
| B | Yes |