Rectifier Assembly
Use the analog type tester to make sure the electrical continuity of each diode meets the chart.
Unless the electrical continuity of each diode meets the chart, replace the rectifier.
TERMINAL CONTINUITY REFERENCE CHART
| (-) side | (+) side | Electrical continuity |
|---|---|---|
| E | P1, P2, P3, P4, P5, P6 | Yes |
| B | No | |
| P1, P2, P3, P4, P5, P6 | E | No |
| B | Yes |