Home >> Mitsubishi >> 2008 >> Outlander LS, AWD >> Repair and Diagnosis >> Maintenance >> Procedures >> General >> How To Use Troubleshooting/Inspection Service Points >> Inspection Service Points For A Blown Fuse

Inspection Service Points For A Blown Fuse

Remove the blown fuse and measure the resistance between the load side of the blown fuse and the ground. Close the switches of all circuits which are connected to this fuse. If the resistance is almost 0 Ω at this time, there is a short somewhere between these switches and the load. If the resistance is not 0 Ω, there is no short at the present time, but a momentary short has probably caused the fuse to blow.

The main causes of a short circuit are the following.

Fig 1: Measuring Resistance Between Load Side Of Blown Fuse And Ground
G05373964Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.