Remote Controlled Mirror Switch Continuity Check
TESTER CONNECTION AND SPECIFIED CONDITION CHART
| Switch position |
Tester connection |
Specified condition |
| Left side |
Up |
1 - 6, 9 - 11 |
Continuity (Less than 2 Ω) |
| Down |
1 - 11, 6 - 9 |
| Right |
1 - 6, 9 - 10 |
| Left |
1 - 10, 6 - 9 |
| Right side |
Up |
1 - 6, 3 - 9 |
| Down |
1 - 3, 6 - 9 |
| Right |
1 - 6, 2 - 9 |
| Left |
1 - 2, 6 - 9 |