LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2007 >> Endeavor LS, AWD >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Specifications >> Service Specification

Service Specification

SERVICE SPECIFICATION

ITEM STANDARD VALUE LIMIT
Fan control module Condenser fan motor connector voltage V
  • When the A/C switch is off.
  • Measure the fan control module-side connector.
1 or less -
  • When the A/C switch is "ON" position.
  • Measure the fan control module-side connector.
Repeat 8.2 +/- 2.6 and Battery positive voltage +/- 2.6 -
Fan control module connector voltage V
  • When the ignition switch is "ON" position.
  • Measure the harness-side connector.
Battery positive voltage -
High-pressure valve opening pressure of radiator cap kPa (psi) 93 - 123 (14 - 18) Minimum 83 (12)
Thermostat Valve opening temperature of thermostat °C (°F) 88 +/- 1.5 (190 +/- 3) -
Full-opening temperature of thermostat °C (°F) 100 (212) -
Valve lift mm (in) 9.0 (0.35) or more -