Service Specifications
SERVICE SPECIFICATIONS
| ITEM | STANDARD VALUE | |
|---|---|---|
| Line pressure kPa (psi) | 1,010 - 1,050 (147 - 152) | |
| A/T fluid temperature sensor kΩ | at 0°C (32°F) | 16.7 - 20.5 |
| at 20°C (68°F) | 7.3 - 8.9 | |
| at 40°C (104°F) | 3.4 - 4.2 | |
| at 60°C (140°F) | 1.9 - 2.2 | |
| at 80°C (176°F) | 1.0 - 1.2 | |
| at 100°C (212°F) | 0.57 - 0.69 | |
| Resistance of torque converter clutch control solenoid valve coil [at 20°C (68°F)] Ω | 2.7 - 3.4 | |
| Resistance of low-reverse solenoid valve coil [at 20°C (68°F)] Ω | 2.7 - 3.4 | |
| Resistance of second solenoid valve coil [at 20°C (68°F)] Ω | 2.7 - 3.4 | |
| Resistance of underdrive solenoid valve coil [at 20°C (68°F)] Ω | 2.7 - 3.4 | |
| Resistance of overdrive solenoid valve coil [at 20°C (68°F)] Ω | 2.7 - 3.4 | |
| Stall speed r/min | 2,100 - 2,600 | |